CLR2160, CLRCO2175 21
4. Check that the clamps and hose connections are tight at
the following areas (see
Figure 36
):
Discharge tube (A)
Drain tube (B)
Vent tube (C)
Figure 36
5. Place a suitable container beneath the pump’s discharge
tube. (The bucket must be able to hold a minimum of
one gallon.)
6. Plug the ice maker power cord into a properly
grounded, polarized electrical outlet.
7. Place the unit into OFF mode by holding power key for
10 seconds. Not doing this will cause the unit to start
the fill cycle which will run for 3 minutes.
8. Verify pump operation by pouring one gallon of water
into the ice storage bin of the ice maker. The pump
should energize and pump the water into the container.
9. At this time, verify that all tube and clamp connections
are tight and leak-free.
10. Unplug unit power cord from electrical outlet.
11. Reinstall back panel.
Locally-Installed Drain Pump
If a gravity drain connection is not possible, and you have
not purchased a CLR2160 or CLRCO2175 with factory-
installed pump, we strongly recommend the use of the
U-Line P60 drain pump. The U-Line P60 drain pump is
available through your Dealer, with complete installation
instructions. If a pump other than the U-Line P60 drain
pump is to be used, it must meet the following
specifications:
It must be UL listed and have a UL listed, 120 VAC,
3-wire grounded power cord.
It must have overall maximum outside dimensions of
8-3/4" wide x 5-3/4" deep x 7-3/4" high.
It must have a minimum flow rate of 1.5 gallons per
minute at 10 feet of lift.
It must have a sealed sump which does not allow water
leakage in the case of a power outage, restricted drain
or pump failure.
It must have a check valve in the discharge line to
prevent waste water return to the pump.
It must have an overflow protection control which will
shut off power to the ice maker in the event of a pump
failure.
It must have an operating temperature range of 50°F
to 110°F (10°C to 40°C).
IMPORTANTIMPORTANT
In the event of a power outage, restricted drain or
pump failure, the failure to use the U-Line P60 drain
pump or a pump with the above listed
specifications, could result in substantial water
leakage and pooling with severe and costly water
damage and related consequential damages and
harm.
Figure 37
Figure 38
Back View Side View
BB
A
CC
ULIN_0575_A
Cold
Water
Hot
Water
Waste
Waste
Shut-Off
Valve
Stand Pipe
P60 Pump Required
ULIN_0571a_A
Air Gap
(Optional Hook-Up)
Cold
Water
Hot
Water
Waste
Shut-Off
Valve
Disposal Assembly
P60 Pump Required
ULIN_0572a_A